Sector of: | Construction products |
Publications in the Official Journal: |
2018/C/092/6 (hEN) |
Commission decision | 1997/740/EC |
Mandates | M/116 Změny mandátu: M/137 M/116am M/116_rev |
Dangerous substances : |
Regulations of the Czech Republic - Dangerous substances SVHC: stone, cement, metal, plaster, plastics Selection of potentialy dangerous substances for Group 17 (CPR): radionuclides (thorium, uranium, radon, potassium), mineral fibres, heavy metals, formaldehyde, benzene; acetaldehyde, tetrachloroethylene, ethylbenzene; trimethylbenzene, toluene; xylene; trichloroethylene, bis (2-ethylhexyl)phthalate (DEHP), dibutyl phthalate (DBP), dichlorobenzene, butoxyethanol, styrene, cadmium and its compounds, arsenic; barium, bromide, chloride, fluoride, total chromium, cobalt, copper, lead, mercury, molybdenum, nickel, selenium, tin, sulphate, vanadium, zinc, polycyclic-aromatic hydrocarbons (PAH): anthracene, benzo[a]anthracene, benzo[a]pyrene, benzo(ghi)perylene, benzo[k]fluoranthene, chrysene, fluoranthene, indeno(1,2,3cd)pyrene, naphthalene, phenanthrene; mineral oil, absence of asbestos (chrysotile, amosite, crocidolite, tremolite, actinolite and anthophyllite) Materials for group 17 (CPR): natural stone, patent stone, clay, concrete, porous concrete, calcium orthosilicate, lime, natural silicate silicate, plastics, cement, metal (galvanized iron, austenitic steel, copper), pigments, organic coating |
EAD code | Full text EAD | Title | First publication in OJEU | TAB notified in NANDO | Assessments systems | Groups (CPR) |
---|---|---|---|---|---|---|
EAD 170005-00-0305 | EAD 170005-00-0305 (EN) | Re-cycled clay masonry units | 2020/1574 29.10.2020 | OS/NB | 2+ | 17 |
EAD 170006-00-0305 | EAD 170006-00-0305 (EN) | Aggregate concrete masonry units with specific moisture conversion factor Fm | 2023/910 04.05.2023 | OS/NB | 2+ | 17 |
EAD 170008-00-0604 | EAD 170008-00-0604 (EN) | Bed joint reinforcement for structural use | 2018/C417/07 16.11.2018 | OS/NB | 3 | 17 |
EAD 170010-00-305 | EAD 170010-00-305 (EN) | Polystyrene concrete masonry units and wall kits made from the units | 2022/1517 12.09.2022 | OS/NB | 1, 2+, 3, 4 | 17 |
EAD 170011-00-0305 | EAD 170011-00-0305 (EN) | Insulating building element for masonry walls | 2020/962 03.07.2020 | OS/NB | 1, 2+, 3, 4 | 17 |
EAD 170012-00-0404 | EAD 170012-00-0404 (EN) | Building blocks made from bricks and cellular glass core | 2023/910 04.05.2023 | OS/NB | 2+ | 17 |
EAD 170018-00-0305 | EAD 170018-00-0305 (EN) | Thermally-insulating and loadbearing units made of cellular glass | 2023/910 04.05.2023 | OS/NB | 1, 2+, 3, 4 | 17 |
EAD 360005-00-0604 | EAD 360005-00-0604 (EN) | Cavity Tray | 2016/C459/08 09.12.2016 | OS/NB | 3 | 17, 35, 36, 22 |